Manufacturer:
(Category: 1800)
used
used
Siemens Uroskop Access in gutem technischen und optischen Zustand Baujahr 2005 alle technischen Unterlagen und viel Zubehör
used
Smicon PT 1500 Fumigation / Fumigation System In a fumigation, a room is flooded with a poisonous gas to fight pests / bacteria. Because they are toxic gases, special safety measures are required. Fumigations are common in the storage of organic materials (eg grain storage, in warehouses of harbors, silos, mills), in addition, in churches to control the woodworm. It is a device which is used for the disinfection of rooms. Formaldehyde is boiled on the left-hand cooking plate and placed in a stream of air in a room together with condensed water (right hearth) to kill all the bacteria. Former list price 9.900EUR
used
Smicon AFT 2/1500 Fumigation / Fumigation plant During fumigation, a room is flooded with a toxic gas to fight pests/bacteria. As these are toxic gases, special safety measures are required. Fumigation is common in the storage of organic materials (e.g. grain storage, in warehouses of ports, silos, mills), and in churches to combat woodworm. It is a device that is used for disinfecting rooms. Formaldehyde is boiled on the left hotplate and placed together with condensed water (right stove top) in an air flow in a room, killing all bacteria there. Former list price EUR 10,900 net More articles - new and used - can be found in our shop! International shipping costs on request!
used
Smicon FTA 1500U-6L fumigation / gassing system In a fumigation, a room is flooded with a poisonous gas to fight pests / bacteria. Because they are toxic gases, special safety measures are required. Fumigations are common in the storage of organic materials (eg grain storage, in warehouses of harbors, silos, mills), in addition, in churches to control the woodworm. It is a device which is used for the disinfection of rooms. Formaldehyde is boiled on the left-hand cooking plate and placed in a stream of air in a room together with condensed water (right hearth) to kill all the bacteria. Former list price 9,900 EUR Item condition: used More articles - new and used - can be found in our shop! International shipping costs on request!
used
We provide the following to the purchase :Prince Technologies PrinCe 560 Capilary Electronic Zone Phorese SystemItem number: 12878Bj 2004Modell PrinCe 560 0500.022/CRS/N: 50-14-05-3-23Dimension:50x50x54 cmWeight: 35 Kgwithout Function test, for more information pls ask us.; Second Hand
used
The BV tests are intended for the detection of biological substances, including botulinum neurotoxins A, B, E and F, staphylococcus enterotoxina A and B, ricin and anthrax spores. BV tests use a sandwich immunoassay format. An anticoerper specific to the pathogen to be measured is immobilized on microparticles. The other anticoacher is labeled with BioVeris' BV-TAGTM label. The sample is mixed with these reagents. When the specific pathogen to be measured is present in the sample, both anticoerpers bind to it and effectively connect the microparticles, the organism and the BV-TAG marker. The reaction mixture is then transported with an assay buffer to a flow cell with an electrode that stimulates the bound BV-TAG label to emit light. Only BV tests provide this unprecedented sensitivity and accuracy. BioVeris M1M Analyzer Incl. Toughbook Panasonic Mod. CF-29HTP44BM Kunstoff Transport (LxW ...
used
A-197 Varian X-ray tubes CE-No. 0086 perm. FILT. 0.7 AL / 75 kVP 150 KL. Focus 0.30 Gr. Focus 0.80 Price on request
used
used
Ladies and gentlemen, below the offer for a used 200 beds hospital The entire technology can be checked before handover. Prices: on request We are also happy to offer you other new and used medical devices. We would be pleased to have your request. All prices are from Station Europa and the dismantling and all follow-up costs are to be made by the buyer. VAT is not included in the prices. The contractual agreements for the individual offers must be agreed separately and only apply after the contract has been signed. Mistake reserved. All technical data are manufacturer or operator information and therefore non-binding for us. Used material is sold to the exclusion of any warranty. We accept no liability for used material. Warranty exchange and return are excluded. Customer protection is agreed between the parties. The entire transport process is carried out at the buye ...
used
Complete HPLC-MS system Agilent 1200 with single Quad ESI mass-spectrometer 6110 E1M18 foreline pump Edwards G1311A quaternary pump G1329A autosampler G1379B micro vacuum degasser G1316A column oven G1314A variable wavelength UV detector Incl. measuring computer / software Tel: 06721-9886710
used
Varian Saturn 2100 T GC/MS system, used Ion trap with Turbo molecular pump Measurement range: 10-650 amu EGG Varian DS 102 backing vacuum pump complete with PC, LCD monitor, and software as well as NIST library Option autosampler: Varian 8400,CTC GC PAL or CTC PAL wagon
new
Complete Shavereinheit with handpiece, foot switch, 2 sterilization box for the Shaverpaltes. 46 Shaverplates Fully functional. Unused, mint condition, used only for demonstration purposes.
X-ray unit Siemens Multix / Vertix with 3D III Deckensrativ and Polydorus LX X-ray Generator
used
Search Dornier Delta or Dornier Delta II Lithotripter / lithotripsy
Multifunction X-ray machine Built in 2005 Generator Poydoros SX 65/80 Image storage LIH (last image hold) Image intensifier 23 cm Tube Optitop 150/30/50 Very good optical condition
Offered is a digital X-ray - workplace, type Siemens MULTIX choice DR Year 2012 in very good condition. System is still in clinical use and will be released beginning March, 2015.
used
Beckman HPLC Plant System Gold, Gradient Pump Model 128 0,01 to 10 ml/min and DAD Detector complete with Software 32 carat
used
Agilent Gaschromatograph model 6890/G 1530A Detector FID/EPC, Injector S/SL /EPC HP-IB and Jetdirect card upon request with Autosampler and Agilent Chemstation
Ladies and gentlemen, follow an offer for a field hospital. The equipment depends on the wishes of the buyer of the field hospital. Of course, containers can also be delivered instead of tents. Below and in the attached annexes, please refer to the corresponding configuration and components of a possible field hospital. They are welcome to adapt to their needs, accept or omit things. The field hospital for 100 people shown here. The equipment is basically optional. We are also happy to supply only the pure hardware component. We can also assist with the construction and operation at any time. If this product is of interest to you, we will be happy to provide you with a complete and detailed offer. All prices are from Station Europa and the dismantling and all follow-up costs are to be made by the buyer. VAT is not included in the prices. The contractual agreement ...
used
Millipore K-Prime III Biochromatography system for cleaning and separation of proteines, biotechnology products, antibodies etc. The System is GMP-conform. floating rate 1-10 l/min, nominal pressure 7 bar, UV-H and LF Messuring after column, fraction sampler valves The System is consisting of corrosion-resistant materialials like lastic and Hastelloy-C.
used
Millipore IsoPak STS, System equipped to pack and unpack columns for Millipore K Prime Biochromatography system year of manufacturing 2000
Ehret Sterilizer ST 637, used, Volume 640 Liter,completely made of stainless steel, Special Design, SPS Control, Process documentation, Temperature +5 to 250 � C Dimensions: W x H x D: 98 x 100 x 68 cm
used
Manifold System Satorius with 3 stainless steal funnel (100ml) for microbiological research
new
VELP OV 625 homogenizer complete with grinding rod and stand New equipment in its original packaging Model No.SA20900470 OV625 Materials: Aluminium – Technopolymers Volume: 0.2 ml – 2.5 L H2O Maximum viscosity: up to 5,000 mPa s Speed: 3,000 – 25,000 rpm Speed Control: Digital Speed adjustment accuracy: 200 rpm With 20mm diameter dispersing tool With stand Power consumption: 800 W Weight: 2.4 kg Dimensions: 92x280x130 mm (3.6x11x5.1 in)
new
THERMO SCIENTIFIC Genesys 40 Dual Visible Beam Spectrophotometer New equipment in its original packaging Spectral range: visible Model GENESYS 40 Range (nm): 325 - 1100 nm Light Source: Tungsten - Halogen Lamp Accuracy: ± 0.5 nm Repeatability: