We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
used
Certus Steam Boiler & Water Tank Type: Junior 500 CVE Manufacture Year: 2012 Please see photos for further specification and information. For more information and more available stock please visit us at - advancedbrewing.co.uk
used
Introducing the Danstoker A-S Boiler – Reliable, Efficient, and Built to Last! Specifications: Model: EEB-W HT Serial Number: 78-6155 Year of Manufacture: 2009 Max. Heat Output: 1005 kW Max. Steam Rating: 6.0 Bar (Design Pressure) Design Temperature: 110°C Test Pressure: 9.0 Bar Water Volume Capacity: 3143 Liters This high-performance boiler is engineered for durability and efficiency, making it ideal for industrial applications. With its robust construction and certified design, the Danstoker A-S ensures reliable operation under demanding conditions. Perfect for businesses seeking a trusted heating solution! for more Details: 07379844145 financeukpowergeneratorsltd.com hashtag#Danstoker hashtag#IndustrialBoiler hashtag#Efficiency hashtag#Reliability hashtag#HeatingSolutions hashtag#EngineeringExcellence Private Notes
used
Volume flow: 60m³/h< br> Head: 30m< br> Electrical power: 7.5kW Auction-ID: A7-49594-7
used
Volume flow: 60m³/h< br> Head: 30m< br> Electrical power: 7.5kW Auction-ID: A7-49594-6
used
Volume flow: 28m³/h Lifting height: 371.51m Electrical power: 55kW Auction-ID: A7-49594-5
used
Type: MTC D 50/10E-4.1 10.81 Year of Make: 2015 Volume flow: 28m³/h Lifting height: 371.51m Electrical power: 55kW Auction-ID: A7-49594-4
used
Power: 143 kW Steam requirement: 2,200 kg/h, 1.8 ba Including condensate tank from Westfalia Wärmetechnik Auction-ID: A7-49594-19
used
grinding diameter: 1520 mmgrinding length: 6000 mmgrinding wheel size: 660 mmsteady: 800 mmsteady: 800 mmtotal power requirement: 15/25 HPweight of the machine ca.: . tdimensions of the machine ca.: . m2 SteadiesCoolant SystemThe data for this ad was created with ModulMWS - the software solution of LogoTech oHG.
used
WEISHAUPT FUEL BURNER - IN WORKING ORDER - LITTLE USED -
used
STEAM BOILER - GAS FIRED MAKE : AMF / CALLENS YOC : 10/1995 CAPACITY : 2.240.000 kcal 2605 kw Pressure : 12,24 kg/cm2 12 bar • With a water supply temperature of 100°C, the steam production should be about 4 tons/hour
used
Steam capacity at 102 ºc of nutritious water --- 10000 kg / h Heat efficiency --- 6.5mW Permissible excess pressure --- 13 Bar Working pressure --- 12 Bar Water content --- 19 m³ Total water content --- 22.6 m³ Transport weight ---- 21,3 t Working weight --- 40.6 t Fuel --- Gas and diesel Manufacturer of water --- Weishaupt Type of water --- Weishaupt G 70 / 2A Water adjustment --- Modulated The heat is the voltage of the current volume --with full fire chamber --- 1.02 mW - without full fire chamber --- 1.21 mW Boiler efficiency - at 100% productivity --- 90% - at 50% productivity --- 90.5% Boilers are still running and video is available on request
used
Steam generation plant, comprising the following main components: - Three-pass steam boiler (Loos) for the production of 2,000 kg/h of saturated steam at rated load - Oil burner (Weishaupt) for EL heating oil with an output of up to 2,145 kW - Economiser (Loos) with approx. 30 m² of heat transfer surface area and an insulated casing - 2 feedwater pumps (Grundfos) - 1,500 l insulated feedwater tank (Loos), horizontal, with feedwater degassing, Additional title: oil-fired three-pass steam boiler with economiser, Steam production capacity: 2000 kg/h ; corresponds to a gross heat output of 1,335 kW, Max. operating pressure: 13 bar, Max. operating temperature: 195 °C, Exhaust gas loss: 4,6 %, Voltage: 400 V, Frequency: 50 Hz, Position: horizontal, Base construction: three-pass design, Features: Steam boiler; oil burner; exhaust gas heat exchanger (economiser); feedwater tank; 2 x feedwater ...
used
Steam generators Manufacturer Beckermesser Type BM 2090 Operating pressure 4 bar Boiler heating 9 kW/h Steam capacity approx. 13.5 Kg/h Water capacity approx. 9.8 litres Documents available
used
The steam boiler plant was put into operation in February 1992 and has been running smoothly for the entire service life since then. The steam boiler has a capacity of NW 7170 ltr and is operated with a maximum operating overpressure of 10 bar. It can run on oil and gas. The steam boiler was regularly serviced and inspected by the TÜV. The last TÜV inspection took place in 2018 without any complaints. The steam boiler has been filled with treated water since its decommissioning in 2019 and can be dismantled and transported away immediately. The closure took place due to a plant closure. The complete documentation is available in the original. Further information, including price, can be requested by calling 0345 6868-0 or infonovachem
used
Three-pass steam boiler (Loos, 1994) with oil and gas firing for the production of 7000 kg/h of steam. The boiler water chamber holds 90 hl of water. Other components: - Combination burner (Saacke) for oil and gas firing - Gas control system - Oil supply with suction pump unit (hp technik) - Economiser (2005) with a heat output of 275 kW - Feedwater tank (Loos, 1994) with a capacity of 40 hl - Water softening system (Pentair, 2024) - Feedwater pump (Grundfos) with a power rating of 5.5 kW - Operating hours counter for oil and gas operation - Control cabinet with operating elements - Various pipework, valves and fittings, Additional title: oil- and gas-fired steam boiler of the three-pass design with an economiser, Steam capacity: 7000 kg/h, Max. operating overpressure: 10 bar, Water volume steam boiler: 9000 l, Position: lying on foundation plate, Base construction: three‑pass boiler d ...
used
Gas-fired high-speed steam generator with feed water treatment and dosage module., Additional title: gas heated, Steam capacity: 120 kg/h, Perm. working pressure: 10 bar, Capacity: 96 Ltr, Set pressure gas burner: 20 mbar, Length: 1,6 m, Width: 0,95 m, Height: 2,2 m, Base construction: mounted on platform, Features: feed water treatment and dosage module
used
Loos Feedwater Module FT C 3 / 0.5 bar - 110°C 3000 liters Year of construction 2009 The plant was operated with osomosis water Destresser/cooler for desalination Sludge Sampling incl. cooler 2 pumps Dosing pump for sulfite phosphate
used
Operating pressure: 10bar, test pressure (PT): 15bar, steam temperature (TS): 184°C, water content: 916l, steam output: 5480kg/h, heating surface (HS): 73.4m², heat output: 3437kW, maximum burner capacity: 3772kW, minimum burner capacity: 1320kW, gas regulator pressure: 150mbar, burner gas pressure: 5 to 65mbar, nominal gas consumption: 406.9Nm³/h, current consumption: 46.2A, length: 3000mm, width: 1900mm, height: 3300mm. Inspection on site is possible.
used
Throughput capacity: 600kg/h, permissible operating pressure: 16bar, fuel: oil, length: 1600mm, width: 1000mm, height: 1900mm. Inspection on site is possible. The machine is not under power.
used
Max. permissible Pressure: 16 bar Test pressure: 30.4 bar Max. permissible Temperature: 204 C Steam capacity: 10000 kg/h Total volume: 16400 l Subject to prior sale - errors possible! Internal reference number: D-1224
used
Max. permissible Pressure: 24 bar Test pressure: 45.6 bar Max. permissible Temperature: 224 C Steam capacity: 12000 kg/h Total volume: 19800 l Subject to prior sale - errors possible! Internal reference number: D-1223
used
An electric steam generator is offered. Steam output: 21kg/h, permissible operating overpressure: 6bar, capacity: 8.2l, heating capacity: 16kW. Equipped with analog pressure gauge, function and fault indicator, filling switch. Inspection possible by arrangement.
used
Two identical Loos steam boiler systems with Weishaupt burners are available. 1) 2x Loos International U-HD 1250 steam boilers, year of manufacture: 2003, max. operating pressure: 10bar, steam output: 1100kg/h, total volume: 1365l. 2) 2x Weishaupt G7/1-D ZD-LN gas burners, year of manufacture: 2003, category: I2ELL, gas type: N, output range: 250kW-1550kW, min./max. connection pressure: 15mbar/500mbar. Both systems including condensate collector and accessories. An on-site inspection is possible. Expected to be available starting 2027.
used
A pure steam generator from the manufacturer Apparatebau Wärmetechnik GmbH, which was distributed by Spirax Sarco, is for sale with a condensate collector. Heat output: 446kW, max. operating pressure in the tubes/around the tubes: 13bar/6bar, operating temperature min./max.: -10°C/200°C, volume in the tubes/around the tubes: 33l/621l, medium in the tubes/around the tubes: saturated steam/steam. Documentation available. An on-site inspection is possible.
used
A professionally dismantled and preserved steam boiler system with a Loos steam boiler and Weishaupt burner is available. 1) Loos UL steam boiler, year of construction: 1991, max. steam output: 6000kg/h, max. operating overpressure: 16bar. 2) Dual fuel burner Weishaupt Monarch RGL 60/2-A, year of construction: 1991, version: ZM, output range: 800kW-6600kW, gas type: N, gas category: I, gas setting pressure range: 30mbar-170mbar, oil throughput range: 120kg/h-556kg/h. Documentation available. An on-site inspection is possible.
used
A compact steam boiler system Gebrüder Lödige is available. Boiler content: 610l, jacket content: 45l, max. boiler operating pressure: 1bar, max. jacket operating pressure: 1.5bar, max. operating temperature: 110°C. Including control box. An on-site inspection is possible. Expected to be available 2026.
used
A horizontal fire-tube/smoke-tube boiler Loos with a 2-pass system is available. Steam output: 2000kg/h, max. operating overpressure: 11.5bar, fuel: oil/gas. An on-site inspection is possible.
used
Three identical Certuss steam generators are available. Year of manufacture: 2008/2009/2010, steam output: 600kg/h, pressure vessel volume: 42.9l, set pressure: 10bar, test pressure: 57bar. Machine dimensions X/Y/Z: 1650mm/900mm/2000mm, weight: approx. 950kg. Documentation available. An on-site inspection is possible.
used
Medium: demineralized feed water (Aqua Purificata), max. vessel operating pressure: 5bar, max. temperature: 200°C, vessel volume: 300l, test pressure: 8.68bar, steam output: 300kg/h. The steam generator was designed as part of an overall system, however it has its own control and automation and can be used in separate operation. Documentation available. An on-site inspection is possible.
used
A complete low-pressure steam boiler system Viessmann is available. 1) Condensate unit Viessmann TWA-T LS 0,9, max. operating pressure: 0.1bar, test pressure: 0.2bar, max. temperature: 110°C, water volume: 400l. 2) Dosing system Schweizer-Chemie EMP 2.5l E60. 3) Steam generator Viessmann Vitoplex 100-LS, year of manufacture: 2019, nominal heat output: 460kW, steam capacity: 700kg/h, water volume: 960l, operating pressure: 1bar, test pressure: 4.8bar. 4) Control cabinet Viessmann Vitocontrol HS. 5) Steam accumulator/pressure vessel Viessmann RBS/1 1000 So. steam, volume shell space/tube space: 990l/17l, max. operating overpressure shell space/tube space: 10bar/2.5bar, max. operating temperature shell space/tube space: 95°C/130°C, test pressure shell space/tube space: 13bar/4bar. Documentation available. An on-site inspection is possible.