We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Manufacturer:
(Category: 1800)
used
For sale is a used, well-preserved Infusomat P from B.BRAUN with drop sensor, power cord and device holder. valid MTK 9/24
used
Zeiss Intrabeam System Irradiation Device, Accelerator. Used in ophthalmic therapy, tumor irradiation. With PTW dosing device. Complete with instruction manual, samples, etc.
used
GE/Amersham Äkta Pilot prep. FPLC; Software Unicorn 5.2, further information on request
used
Agilent 5975C inert MSD with GC 6890N Agilent 5975 C inert MSD, Agilent GC 6890 N Pfeiffer Turbomolecular Pump, Electronic Ionization/EI ; GC Injector Split/splitless, EPC, LAN Agilent Backing Pump, Software Agilent MSD Chemstation for Win10
used
Perkin Elmer HS 40, Headspace sampler for 40 vials, max. temperature + 210 Celsius, min. +35 Celsius, fits all gas chromator graphs,
used
Fuji Capsula XL II CR System incl. PC / Monitor / Keyboard / CD / manuals tested from technican #Welcome to inspect & test # EXW Germany
used
Siemens swivel arm / U-arm X-ray imaging workstation with the following system components: Alternator Polydoros LX 30/50, Tube Opti 150/30/50 HC 1x detector Protec Rapixx 4343 M2i Workstation Patient couch • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • The installation, commissioning and configuration of the system or ...
used
Used Tecan Freedome evo 200 pipetting robot with TE-MO 3/5 Pictures will follow
used
Used pipetting robot Tecan EVO 150 with Tecan dongle and CDs and accessories .
used
Rofin StarCut Tube Fiber Stent Cutting System Used Year of construction : 2012 Lasers For cutting almost all metal alloys and plastic compounds commonly used in medical technology. Pictures will follow !
used
Used Thinking Super Cascom Dental Die Casting Machine Year of manufacture : 2014 Think compressor ! Year of construction : 2015
used
Nova BioProfile Flex Automated Cell Culture Analyzer BioProfile is an automated cell culture analyzer that measures up to 15 important cell culture attributes. By combining up to five separate instruments into one easy-to-use instrument, BioProfile FLEX simplifies workflow and saves time, labor, and operating costs compared to multiple instruments. The FLEX automatic sampler takes samples from its two fermenters and transmits them to the measuring unit of the FLEX analyzer. The data obtained from the FLEX autosampler were compared with data taken manually from the reactor and their statistical analysis was performed. Specifications Sample analysis time: 2.5 minutes (gases only – PO 2 + PCO 2 ), 4.0 minutes (Chemistry/Gas and Osmolality), 6.25 minutes (all 15 tests), Operating temperature range: 15-30 °C (59-86 °F), Relative operating temperature Humidity range: 20-85 ...
used
AGFA Imaging Plate System / CR System CR 30-X (for Veterinarian) Primary processing station 3 CR cassettes • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • The installation, commissioning and configuration of the system or system components must be carried out by the manufacturer or by a specialist or technician authorized b ...
used
Siemens combined X-ray recording and fluoroscopy device Iconos R 200 with the following system components: Generator Polydoros SX 65 Tube Optitop 150/40/80 HC 0,6/1,0 Digital image processing Fluorospot Compact Sirecon 33-4 HDR image intensifier • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • The installation, commissioning and configuration of the system or system components must be carried out by the manufactur ...
used
AGFA / Siemens X-ray imaging workstation DX-D 500 (digital) with the following system components: Generator Siemens Polydoros IT 80 Tube Siemens SV 150/40/80 HC 0.6/1.0_Bj. 2018 Vertical tripod Siemens Vertix T Fa. Siemens 2x detector VARIAN 4343R CSi_43x43cm Workstation • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • T ...
used
AGFA / Siemens X-ray recorder DX-D 500 (digital) with the following system components: Generator Siemens Polydoros IT 80 Tube Siemens SV 150/40/80 HC 0.6/1.0 Vertical tripod Siemens Vertix T 2x detector VARIAN 4343R CSi_43x43cm Workstation • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • The installation, commissioning ...
new
Carbolite Gero AX30 Heating Oven Original price 3385 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 918 Holding power (W) 342 Weight (kg) 24 Condition: new, without original packaging ...
new
Carbolite Gero AX30 Heating Oven Original price 3185 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. The tabletop units are equipped with R38 PID controllers as standard. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 1000 Holding powe ...
Siemens X-ray system type Multix Select DR Very good technical and optical condition
Siemens X-ray system type Multix TOP with Vertix TOP with 3D3 ceiling suspension Very good technical and optical condition
used
mytron 160 K CO2 Double Incubator The CO2 Incubator 160 / 160K provides the "in vitro" growing cell and tissue cultures with environmental conditions that are very close to the physiological values of the organism. Interior volume: approx. 160 l Weight: 70 kg Recirculating air circulation: by fan Cooling: Cooling unit Temperature display: Setpoint and actual value display Temperature range: 5 °C above room temperature to 70 °C Temperature range (cooled): +15°C to 70°C at 23°C ambient Temperature constancy: +/- 0.2 K temporal Humidity display: setpoint and actual value display Humidity range: >/=95 % Moisture resistance: +/- 2.5 % CO2 display: setpoint and actual value display CO2 range: 0% to 20% CO2 CO2 constancy: +/- 0.2 % CO2 CO2 recovery time: 1% CO2/min Power supply: 230 V, 50 Hz, 2 x 8 AT WxHxD= 130x85x70 cm Buy incubators and other products at low pric ...
used
mytron 160 K CO2 Double Incubator The CO2 Incubator 160 / 160K provides the "in vitro" growing cell and tissue cultures with environmental conditions that are very close to the physiological values of the organism. Interior volume: approx. 160 l Weight: 70 kg Recirculating air circulation: by fan Cooling: Cooling unit Temperature display: Setpoint and actual value display Temperature range: 5 °C above room temperature to 70 °C Temperature range (cooled): +15°C to 70°C at 23°C ambient Temperature constancy: +/- 0.2 K temporal Humidity display: setpoint and actual value display Humidity range: >/=95 % Moisture resistance: +/- 2.5 % CO2 display: setpoint and actual value display CO2 range: 0% to 20% CO2 CO2 constancy: +/- 0.2 % CO2 CO2 recovery time: 1% CO2/min Power supply: 230 V, 50 Hz, 2 x 8 AT WxHxD= 130x85x70 cm More items new and used - you can find them ...
used
GE Äkta Explorer FPLC 100 Air/General Electric/Cytiva -Box 900 -pH/C 900 monitor -UV 900 UV Detector -UV Flow Cell -P 900 Pump /100ml/min w. Switch Valves Air 900 Control Box -pH Sample -Conductivity Cell -INV 907 Injection V1 Sample Valve V5 Outlet Valve V4 Column Valve V2 Column Valve V 3 -P 960 -M 925 MIxer (2ml) on request 5 and 12 ml) FR 902 Restrictor CU-950 Interface Unicorn Software -Frac 950 Faction Collector warranty
used
Carbolite CWF 11/5 Chamber Furnace 1100 °C Max Temp: 1100 °C With suction device and table The upward-opening door keeps the hot surface away from the user Gently self-closing door (for 5, 13, 21 & 23 litre models) Standard start-up delay and process timer function Durable alumina backing plates for the heating elements; Robust door frame and base plate High-quality fiber insulation with low thermal mass Powerful heating elements on both sides ensure very good temperature homogeneity Easy access to elements and controls simplify maintenance and servicing More items new and used - you can find them in our shop! International shipping costs on request!
used
Hitachi HPLC System LaChrom Elite -Power Box -L 2130 Gradient Pump -L 2300 Column Thermostat -L 2200 Autosampler (cooling) -L2455 DAD Diode Array Detector
used
Agilent G 1362 A RID Detector Refractive Index Range 1.00-1.75 RIU Measurement Range +/- 600x 10-6 RIU Sample Cell 8 ul Analog Output/Recorder/Integrator 100mV or 1 V Communications: CAN, GP-IB, RS 232; LAN
used
Agilent G 1321A Fluorescence Detector Ex Monochromator range 200 – 700 nm Em Monochromator range 280-900 nm Wavelength characteric Repeatability +/- 0.2 nm Accurcacy +/- 3 nm Flow cell 8μl Analog Output/Recorder/Integrator 100mV or 1 V Communications: CAN, GP-IB, RS 232; LAN Remote: ready, start, stop and shut down signals
used
Agilent 5973 N MSD Detector with Edwards turbomolecular pump or diffusion pump, used and refurbished on request also complete as measuring station with Agilent 6890GC Please inquire about the price per piece
used
GE Äkta Purifier 10 FPLC System Box 900 P 900 Pump /10 ml pump heads UPC 900 Monitor INV 907 Valve M925 Mixer / 6 ml mixing chamber Conductivity Flow Cell pH Sample CU 950 Interface/Communication Module FRAC 920 Fraction Collector Unicorn Software
used
Agilent 5973N inert MSD with GC Agilent 6890 N Agilent 5973 N inert MSD with GC Agilent 6890 N Network Agilent 5973 inert MSD with EI and turbomolecular pump enhanced BOC Edwards Turbopump Agilent GC 6890 Network with Split/Splitless Injector/EPC Edwards Vacuum Pump 1.5 MSD Productivity Chemstation E02.02 on PC/Win 10 NIST on request Option: Agilent Liquid Sampler, CTC or Gerstel MPS2 Sampler currently serviced/with warranty Installation on request