We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Manufacturer:
(Category: 1101)
used
Heat and Power Plant with an Absorption Chiller An 850 kW combined heat and power plant with an absorption chiller. The systems ran perfectly until the end and all maintenance was carried out. No damage is known. The CHP ran for 51,429 hours of operation. The absorption chiller has run for 42,350 hours. The following components use an overhauled long block or completely overhauled. The components relevant to assemblies for "modernization" were marked: - complete panelling - Interfaceschronk - Oil relubrication pump Mechanically overhauled and electrically tested - Oil level monitoring - Plotter heat exchanger" - Pressure expansion foll3 (if present) - Pressure transducer and temperature sensors - Rubber rails for motor and generator - Clutch element - Air filter inserts - Safety valves and arnot inserts - Sylomer strips - Hot water preheating pump and heating el ...
used
BHKW engine type HCI534E2 for sale Combustion engine TEDOM type DC16 1-013-826. The motor block was only completely replaced in May 23 It is still entitled to EEG compensation until 2031. Find more here - / Contact us at -
used
Steam turbine for sale. The turbine was built in 2012, is in good condition and is no longer in operation. Model SST-060 Turbine with impeller in so-called constant-pressure design ("action wheel"). The turbine rotor is mounted on two bearings and consists of the above-mentioned impeller and a shaft, which are connected to each other by means of Hirth gearing. The impeller is located outside the bearing and consists of one piece. The blades are milled out of the solid disc. Live steam pressure: 13.0 ´bara at turbine flange Live steam temperature: 191.6 ´C at turbine flange Live steam flow max: 10,000 kg/h Exhaust steam pressure: 5.2 bara at turbine exhaust flange Turbo generator sound pressure level: 92 dB(A) z 3 dB(A) measured at a distance of 1 m Coupling power: 275kW Total terminal power: The tolerance is 1.0%. 265kWe The pressure drop for the cyclone to be provided sh ...
used
2x GE Frame 6B gas turbines # Technical Summary Equipment Details - Gas Turbines: Two GE MS 6001 B gas turbines paired with AEG generators (Type S7102/2). - Operation History: - Commissioning: 1981 - Gas-fired Operation: Until 2005, primarily for base load (~7000 hours/year). - Operational Hours in Combined Cycle: - GT21: ~167,000 hours, ~1130 starts - GT22: ~159,000 hours, ~1180 starts - Retrofitted: In 1996 with water injection for NOx reduction. - Conversion: In 2007 to peak load operation using heating oil (HEL) with new steel chimneys and upgraded control systems to ABB Procontrol 14. - Operational Hours in Peak Load: - GT21: ~130 hours, ~177 starts - GT22: ~150 hours, ~180 starts - Last Network Operation: 2015 - Last Oil Service: - GT21: October 2015 - GT22: September 2016 - Last Borescope Inspection: December 2016 - Defect: Heating oil transfer line issue in 2 ...
new
Key data: 648 KW, 810 kVA
Caterpillar 3412C Generator Sets – 2014, Unused • Quantity: 9 units • Prime Power: 810 kVA / 648 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3412C diesel • Condition: Unused, factory new Key Features: IP22 protection, H insulation, standard CAT excitation, suitable for industrial continuous-duty applications in 50 Hz markets. Caterpillar 3406C Generator Sets – 2014, Unused • Quantity: 5 units • Prime Power: 275 kVA / 220 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3406C diesel • Condition: Unused, factory new Key Features: IP23 enclosure, H insulation, star-connected generator, ambient rating up to 50°C.
new
Key data: 648 KW, 810 kVA
Caterpillar 3412C Generator Sets – 2014, Unused • Quantity: 9 units • Prime Power: 810 kVA / 648 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3412C diesel • Condition: Unused, factory new Key Features: IP22 protection, H insulation, standard CAT excitation, suitable for industrial continuous-duty applications in 50 Hz markets. Caterpillar 3406C Generator Sets – 2014, Unused • Quantity: 5 units • Prime Power: 275 kVA / 220 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3406C diesel • Condition: Unused, factory new Key Features: IP23 enclosure, H insulation, star-connected generator, ambient rating up to 50°C.
used
Key data: 19305 KW, 24132 kVA, 11000 V
We are pleased to present the data and technical information for a MAN-based power plant with total capacity of 58 MW, including full operational history. Below is our sale proposal for three (3) MAN 18V48/60 TS diesel generator sets, offered together with Balance of Plant (BOP). 1. Engine Details Manufacturer: MAN Turbo & Diesel Model: 18V48/60 TS Rated Output: 19,305 kW (continuous) per unit Fuel: HSD (diesel); can be converted to HFO with fuel heating system modification Speed: 500 RPM Serial Numbers: 1135657, 1135658, 1135659 2. Alternator Details Manufacturer: ABB Rating: 24,132 kVA Voltage: 11,000 V Frequency: 50 Hz Power Factor: 0.8 3. General Information Quantity: 3 generator sets Manufacturing Year: 2014 First Operation: January 2016 Average Running Hours: approx. 5,000–6,000 hours Status: Very good condition, fully operational Application: B ...
used
Key data: 3024 KW, 3780 kVA, 10500 V
For sale is a LEROY-SOMER LSA L54 XL10-4P generator with serial number 600194/1. This generator was coupled with a Jenbacher 620 engine with the design number B677. The generator delivers a power of 2530 kVA at an output voltage of 400 V. It was manufactured in 2016 and has only 500 hours of operation since then. The price for this powerful and hardly used generator is 30,000 euros. Please do not hesitate to contact us for more information or to arrange a viewing.
used
Key data: 1068 KW, 1335 kVA, 400 V
For sale is a Newage generator with the serial number A12H327489. This generator was coupled with a Jenbacher 320 engine with the design number O988. The generator delivers an output of 1335 kVA at an output voltage of 400 V. It was manufactured in 2012. The price for this powerful and hardly used generator is 7,000 euros. Please do not hesitate to contact us for more information or to arrange a viewing.
used
3x Container Power Generators NEW PLANTS! Cummins QSK60-G4 LTP power: 2233 kVA PRP Power: 2030 kVA Year: 03/2026 Operating hours: None Speed: 1500 1/min Tank approx. 4000 liters Generator: Mecc Alte ECO46 1L/4 Voltage: 400/231 V, 50 Hz Generator circuit breaker 4000 A, battery charger, cooling water preheating, DEIF control AGC4-MK2 for Island and parallel operation. Warranty: 12 months or 1000 hours after delivery, whichever comes first. Individual sale possible. Subject to prior sale - errors possible! Internal Reference Number: E-1004-105
used
Key data: 526 KW, 910 kVA, 400 V
Jenbacher JMS 312 GS-B.LC - Container Design Number: F866 Year of construction: 2009 Country: Switzerland Site Name: Aarberg Module number: 803588 Engine number: 6128071 Serial number: 323762 Engine type: 312 Engine version: C225 Gas type 1: Biogas Control System: Dia.ne XT Power Output: 544 kW Electrical Output: 526 kW Thermal output: 505 kW Alternator: NEWAGE Type: HCI 634 H2 Type Rating: 910kVA Voltage 400V Frequency: 50Hz Turbocharger: PBST Type: TCR12-42516 Actual OH: 126,000 Starts: 5543 Service: Equipment was serviced by IWK (authorized Service Partner of INNIO for Switzerland). At 60k OH the Longblock was exchanged, at 105k OH the Minor Overhaul (40k) was done. Till next Major Overhaul the engine has approx. 15k OH left.
used
used
used
used
used