Manufacturer:
(Category: 1101)
used
Manufacturer: Wurz Energy Year of Manufacture: 2009 Type of Machine : 340 CHP (Combined Heat and Power) Diesel Generator Set Electrical Power: 340 kW each Thermal Power: 346 kW each Engine: SCANIA DC16-RP Control System: SIEMENS / SCANIA CAN BUS Fuel Consumption: up to 245 g/kWh Fuel: palm oil, rapeseed oil, biodiesel, diesel Operating Hours: 10–13 each (maintenance only) Condition: New, unused Container: 20 ft, approx. 9,500 kg each Find more here - / Contact us at -
used
Manufacturer: COMUNA-Metall Model: 2726-02 Type of Machine : CHP Plant Nominal Heat Load: 156 kW Thermal Output: 92 kW Electrical Output: 50 kW Operating Voltage: 230/400 V, 3-phase, 50 Hz Fuse Rating: NH00, 100A Connection Pressure: 20–80 mbar Max Operating Pressure: 6 bar Operating Temperature: 100/70 °C Protection Class: IP54 Certification: DIN DVGW Find more here - / Contact us at -
used
Engine: Volvo TWD 1620G Generator: A.v. Kaick DSG 62 M2-4 Dimensions: 3.88 m (L) × 1.1 m (W) Operating Hours: 389 hours Service History: - Last service: 06/2025 - Next scheduled service: 12/2025 - Last oil change: 12/2024 at 361 hours Find more here - / Contact us at -
used
Manufacturer: KKK Model: CF 5 G Year of Manufacture: 1986 Output Power: 412 kW Inlet Steam Pressure: 19 bar (Normal) Outlet Steam Pressure: 3 bar (Normal) Inlet Steam Temperature: 300°C (Normal) Alternator Features: Brand: AVK Alternator Type: DKBN80/500-4TS Power: 482 KVA (400 V, 696 A, 50 Hz) Year of Manufacture: 1986
used
Manufacturer: Siemens Model: SST-060 Year of Manufacture: 2016 Output Power: 1006 kW (nominal) Speed: 1500 rpm (nominal) Trip Speed: 1605 rpm Live Steam (Inlet Pressure): - Min: 20.6 bar - Nominal: 23.0 bar - Max: 25.4 bar Live Steam (Inlet Temperature): - Min: 300 °C - Nominal: 350 °C - Max: 378 °C Exhaust Steam (Outlet Pressure): - Min: 2.10 bar - Nominal: 3.10 bar - Max: 4.10 bar Exhaust Steam (Outlet Temperature): - Max: 331 °C Find more here - / Contact us at -
used
Manufacturer: Atlas Copco Model: ZE 4 VSD (51 psi) with aftercooler Type of Machine : air compressor Temperature at max operating pressure: 40 °C Nominal pressure levels: 2.25 – 3.5 bar(e) Max. effective operating pressure: 2.25 – 3.5 bar(e) Min. effective operating pressure: 1.05 – 3.0 bar(e) Max. motor speed: 1200 U/min Electrical power consumption: 214.8 – 254.1 kW Air outlet temperature at max load: 40°C Required oil volume: 55 L Sound pressure level: 82 dB(A) Find more here - / Contact us at -
used
Manufacturer: Model: Power: 12,000.00 kW Voltage: 10,000.00 V Y Speed: 1,500.00 rpm Rated motor current: 788 A Rated frequency: 50 Hz Rated motor speed: 1,494 rpm Power factor (cos φ): 0.88 (50%), 0.90 (75%), 0.85 (100%) - Efficiency (EN 60034-2-1:2008): - 50%: 96.8% - 75%: 97.4% - 100%: 97.2% Starting/Rated current (Ia/In): 5.0 Starting/Rated torque (Ma/Mn): 1.9 Breakdown/Rated torque (Mk/Mn): 2.3 Mechanical Data - Number of poles: 4 - Weight: 29,000 kg - Frame size: 900 - Type of construction: IM B3/D5 - Housing material: Welded steel - Terminal box material: Welded steel - Bearing type: Sleeve bearing with circulating lubrication (both DE and NDE) - Rotor inertia: 540 kgm² - Cooling method: IC81W (water cooling) - Water inlet temperature: 28°C - Water quantity: approx. 50 m³/h Including base plates for size adjustment Environmental and Operating Conditions - Ambie ...
used
Manufacturer: MTU Model: GC370B5 Year of Manufacture: 2015 Operating Hours: O Weight (with/without fluids): 5000 kg / 4700 kg Performance Class: G1 Electrical Specifications: - Electrical Power (COP): 370 kW - Nominal Voltage: 400 V - Nominal Frequency: 50 Hz - Rated Power Factor (cos φ): 0.8 / 0.95 - Max. Outdoor Temperature: 25°C - Max. Installation Height: 100 m a.s.l. Heat Extraction (DIN 6280): - Thermal Output: 401 kW - Admissible Water Temperature (min/max): 70°C / 90°C - Admissible Overpressure in Heating Circuit: 16 bar Table cooler, chimney, everything included. Find more here - / Contact us at -
used
For Sale: Complete 10 MW / 2 MW Cogeneration Power Plant Available for immediate acquisition: a fully integrated power plant for the combined and efficient production of heat and electricity through a cogeneration system. Technical Description: The whole installation (Model: E.V.A.) for sale includes components listed below: STEAM BOILER Manufacturer: Wehrle Werk Year: 1999, Heating capacity: up to 10 MW Fuel type: biomass/RDF Fuel gas volume: 20.000 Nm³/h Fuel consumption: approx. 2500 kg/h Fuel need: approx. 20 000 t/a Average combustion temperature: approx. 900°C Main steam pressure: water steam with 40 bar Main steam temperature: 410°C Main steam mass flow: 11 t/h Combustion power gross: max. 10.000 kW Combustion power gross: min. 7000 kW Water content: 25 m³ STEAM TURBINE Manufacturer: KKK / Siemens SST110 Electrical capacity: up to 2 MW Year: 1999, serial ...
used
We are offering for sale a Motor Accessories Package that includes the following machines: Machine 1 Manufacturer: AEG Model: AR630S6B2KB Year: 1990 Enclosure: IP54 Shaft: Ø110 mm, 210 mm length Motor Type: High Voltage Motor Power: 1400.00 Speed: 2989 RPM Voltage: 5000 V Poles: 2 Machine 2 Manufacturer: AEG Model: AR500M6B4KB Year: 1992 Enclosure: IP54 Shaft: Ø100 mm, 210 mm length Motor Type: High Voltage Motor Power: 600.00 Speed: 1492 RPM Voltage: 5000 V Poles: 4 Machine 3 Manufacturer: SCHORCH Model: D3AK 5832/4R Year: 1970 Enclosure: IP33 Shaft: Unknown Motor Type: High Voltage Motor Power: 900.00 Speed: 1490 RPM Voltage: 5000 V Poles: 4 Machine 4 Manufacturer: SIEMENS Model: 1MA1 566-4XZ50-Z Year: 1995 Enclosure: 54 Shaft: Ø140 mm, 250 mm length Motor Type: High Voltage Motor Power: 1400.00 Speed: 1494 RPM Voltage: 5000 V Poles: 4 Ma ...
used
Manufacturer: MWM Model: TCG 2016 V8 C CHP unit 1 Operating Hours: 22,057 h CHP unit 2 Operating Hours: 9,112 h In addition to the two units themselves, the sale also includes exhaust gas heat exchangers, engine and auxiliary drive control systems, visualization, and a comprehensive spare parts package. Performance Data (Biogas, 50 Hz) - Electrical Output: 400 kWₑ - Voltage / Frequency: 400 V / 50 Hz - Speed: 1500 rpm - Generator: Marelli MJB 355 MB4 - Motor Management System: TEM EVO Efficiency - Electrical Efficiency: 38.0 – 46.4% - Thermal Efficiency: 40.4 – 43.6% - Total Efficiency: Up to 84.4% Engine Configuration - Type: V8 - Bore / Stroke / Displacement: 132 mm / 160 mm / 17.5 liters - Fuel Type: Biogas Heat Recovery (±8%) - Cooling Water Heat: 2080 kW - Mixture Cooler Heat: 5340 kW - Oil Heat: 12000 kW - Exhaust Heat (at cooling): 1136 kW - Radiant Heat (Engine ...
used
Oil-Insulated Power Transformers for Sale Transformer 1 - Manufacturer: ELIN - Model: TDQ-164A11S9K-99 - Power Rating: 15 MVA - High Voltage: - 121.5 kV (Position 0) - 118.463 kV (Position -1) - 115.425 kV (Position -2) - Low Voltage: 6.3 kV - Current Rating: - High Voltage: 71.3 A (Position 0), 73.1 A (Position -1), 75.05 A (Position -2) - Low Voltage: 1375 A - Frequency: 50 Hz - Cooling: ONAN - Year of Manufacture: 1994 - Status: Out of service since 2022 - Notable Condition: Relatively high CO levels (due to oxidation); insufficient oil inhibitor content. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale Manufacturer: ELIN Model: TDY-164A11S9K-99 Power Rating: 15 MVA High Voltage: - 121.5 kV (Position 0) - 118.463 kV (Position -1) - 115.425 kV (Position -2) Low Voltage: 6.3 kV Current Rating: - High Voltage: 71.3 A (Position 0), 73.1 A (Position -1), 75.05 A (Position -2) - Low Voltage: 1375 A Frequency: 50 Hz Cooling: ONAN Year of Manufacture: 1993 Status: In operation until 2025 Notable Condition: High CO levels, insufficient oil inhibitor content. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale - Manufacturer: ELIN - Model: JDR 8000/110 - Power Rating: 8 MVA - High Voltage: - 124.85 kV (Position 9) - 110 kV (Position 0) - 95.15 kV (Position -9) - Low Voltage: 25 kV - Current Rating: - High Voltage: 37.5 A (Position 9), 42.0 A (Position 0), 47.7 A (Position -9) - Low Voltage: 185 A - Frequency: 50 Hz - Cooling: ONAN - Year of Manufacture: 1960 - Status: Out of service since early 2024 - Notable Condition: Low oil inhibitor content and specific resistance; otherwise, oil is in good condition. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale Manufacturer: Brown Boveri Model: TRFKa 1350/30 Power Rating: 1350 kVA High Voltage: - 26.25 kV (Middle position) - 27.56 kV (Position 1) - 24.93 kV (Position 5) Low Voltage: 6.3 kV Current Rating: - High Voltage: 29.7 A (Middle position) - Low Voltage: 124 A Frequency: 50 Hz Cooling: ONAN Year of Manufacture: 1972 Status: In operation until March 2025 Notable Condition: High CO levels and water content; oil drying and treatment recommended. Find more here - / Contact us at -
used
Manufacturer: COMUNA-Metall Year of Manufacture: 2008 Gas type: Category 12HL Connection pressure: 20-50 mbar Nominal power range: 150/195 kW Voltage: 230/400V, 3-phase, 50Hz Fuse: NH 00, 100A Permissible operating pressure: 6 bar Thermal power: 100 kW Electrical power: 50 kW Protection class: IP 54 Permissible operating temperature: 90/70°C Find more here - / Contact us at -
used
Manufacturer: KW Energie Model: Smartblock Year of Manufacture: 2014 Type of Machine: CHP Plant Operating Hours: 17,000 Fuel Type: Natural Gas Engine: Kubota Electrical Output: 22 kW Thermal Output: 50 kW (with condensing boiler use) Fuel Input: 68.4 kW Condition: Fully functional Motor Data - Model: Kubota R24 - Type: Four-Stroke Otto Engine - Cylinder Count: 4 - Displacement: 2.4 Liters - Nominal Speed: 1500 rpm Efficiency Data - Total Efficiency: 105.3% - Electrical Efficiency: 32.2% - Thermal Efficiency: 73.1% - Primary Energy Savings: 34.1% - Primary Energy Factor: 0.36 - Overall Annual Utilization Rate: 105.3% Gas Connection Data - Gas Supply Pressure: 20-50 mbar - Gas Flow Pressure: 16 mbar - Volume Flow (at 0°C, 1013 mbar): 6.8 Nm³/h Temperature Data - Flow Temperature: Max. 85°C - Return Temperature: Max. 65°C - Combustion Air Demand: Min. 75 m³/h - Room ...
used
Manufacturer: TEDOM Model: FLEXI 250 Year of Manufacture: 2022 Type of Machine: Combined heat and power plant (CHP) Primary Circuit - Nominal Heat Output: 369 kW - Max. Permissible Pressure: 3.5 bar - Max. Permissible Temperature: 95°C - Category: II - Nominal Size: 100 - Fluid: Water-Ethylene Glycol - Volume: 350 L Secondary Circuit - Nominal Heat Output: 369 kW - Max. Permissible Pressure: 10 bar - Max. Permissible Temperature: 90°C - Category: Article 4, Section 3 - Nominal Size: 80 - Fluid: Water-Propylene Glycol - Volume: 56 L Reversible heat pump Manufacturer: Mitsubishi Model: NX2-N-G06 /A /0606 Type: Reversible, air-cooled heat pump Function: Heating and cooling Power Supply: 400V / 3-phase / 50Hz Find more here - / Contact us at -
used
Manufacturer: Ansaldo Year of Manufacture: 1999 Technical Data Listing Generator - Type: Three-phase synchronous generator GSCR 800Y4 - Power: 7,250 KVA - Voltage: 10,500V - Frequency: 50 Hz - Phase Number: 3 - Number of Poles: 4 - Rated Current: 398.8A - Power Factor: 0.80 - Rated Speed: 1,500 rpm - Spin Speed: 1,800 rpm - Insulation Heat Resistance Class: F - Ambient Temperature: 40°C - Moment of Inertia of the Rotor: 118.75 kgm² - Winding Connection: Star - Excitation Voltage Rating: 41.2/158.3V - Rated Excitation Current: 54.2/152.3A - Operation Mode: Continuous - Protection Class: IP 4 - Cooling Water Quantity: 660 l/min - Cooling Water Inlet Temperature: 40°C - Cooling Water Inlet Pressure: 4 bar - Air Inlet Temperature: 45°C - Bearing Type: Rolling bearing - Bearing A-side: EMZLB18-200 - Bearing B-side: EMZLQ18-200 - Min. Clearance Shaft/Bearing: 0.267mm - Max. Clearance S ...
We are currently offering for sale an almost new 50 kW CHP plant from Tuxhorn. Specifications: - Model: E50SW (Natural Gas Version) - Year of Manufacture : 2022 - Commissioning Date: February 2023 - Operating Hours (BH): 45 - Number of Starts: 59 Special Features: - Equipped with a second exhaust gas SD, reducing exhaust noise to as low as 35 dB(A) for quieter operation. Condition: - Excellent: The unit is in like-new condition with minimal usage. Applications: - Ideal for industrial or commercial operations requiring reliable and efficient combined heat and power. Find more here - / Contact us at -
used
Thermostat, Cooling Water Temperature Controller, Thermostatic MERTIK542.83Switching Temperature: 80° CMain Connections: Ø 50 mmSecondary Connection: Ø 32 mmMaterial: BrassNew !Dimensions: 180 x 160 x 100 mm
used
Frequency converter, frequency converterLOHERFUV 160L2/160L1/6Input: 380 V 28 AOutput: 265 V 48 A 200 HzPower: 22 KVAused, tested ! Image similar !Dimensions: 1030 x 540 x 340 mm
used
GeneratorAEMWH 400 L 4690 V910 kW60 Hz1815 rpmshaft diameter: Ø 110 mmDimensions: 2200 x 1400 x 1100 mmWeight approx. 3..8 TonNew !
used
DC Generator for DDR Crane MotorsVEMGGB 180.1K ( GGB180.1K )TGL 20675 ( TGL20675 )6.2 kW230 V DCmotor: 7.5 kW1435 rpm380 Vused, tested ! Dimensions: 1090 x 360 x 540 mm
used
GeneratorEMEDRS 200/10-8year: 2005115 V52,2 A107 HzShaft diameter: Ø 40 / 45 mmNew !' Dimensions: 730 x 460 x 470 mm
used
2007 Mercedes Combined heat and power plant (CHP) The CHP plant was originally intended for an oil platform. Therefore, it is protected against salt water and can also be operated in island mode. Technical data (See pictures) CHP plant with Mercedes engine, which is designed for multi-quality fuel (diesel, heating oil, pyrolysis oil or vegetable oil). Thus preheating unit and corresponding exhaust gas purification. BJ. 2007. Operating hours: 0 (test run only); The unit was never connected to the network. If palm or vegetable oil is used, preheating” is required to get above the pour point. All pumps were completely overhauled by the manufacturer when we purchased them (see Rg with maintenance report). If you want to drive in island mode, this must be changed on the control + the controller on the generator must be replaced. In addition to electricity, the unit can also recover ...
used
Engine: Jenbacher Works 4T6S Generator: 725kW Diesel powered We installed the unit in a 20-foot container a few years ago. It is fully functional and working. Find more here - / Contact us at -
used
Backup power generator LIKE NEW! The current number of operating hours is 21 hours . Manufacturer Zeppelin CAT Model PPO2000-C32 Year of manufacture 2007 Weight 26t Dimensions (L/W/H) 11,0m / 3,0m / 3,2m Condition Very good (used) Remarks/ Info: Engine overhauled in 2014 400 Volt 50 Hz 1200 KW 2000 kVA 1500 rpm According to this, the CAT engines have been completely reconditioned (according to Zeppelin, the engine is better in the repair ,as a new engine) . The current number of operating hours is 21 hours . The machine has been standing since 2014 . We were to a performance test last month at Cat Zeppelin ,there the machine has full power without complaint passed the test . The number of operating hours refers to both engines and the generator. Find more here - /