We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Manufacturer:
(Category: 1101)
used
used
used
Oil-Insulated Power Transformers for Sale Transformer 1 - Manufacturer: ELIN - Model: TDQ-164A11S9K-99 - Power Rating: 15 MVA - High Voltage: - 121.5 kV (Position 0) - 118.463 kV (Position -1) - 115.425 kV (Position -2) - Low Voltage: 6.3 kV - Current Rating: - High Voltage: 71.3 A (Position 0), 73.1 A (Position -1), 75.05 A (Position -2) - Low Voltage: 1375 A - Frequency: 50 Hz - Cooling: ONAN - Year of Manufacture: 1994 - Status: Out of service since 2022 - Notable Condition: Relatively high CO levels (due to oxidation); insufficient oil inhibitor content. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale Manufacturer: ELIN Model: TDY-164A11S9K-99 Power Rating: 15 MVA High Voltage: - 121.5 kV (Position 0) - 118.463 kV (Position -1) - 115.425 kV (Position -2) Low Voltage: 6.3 kV Current Rating: - High Voltage: 71.3 A (Position 0), 73.1 A (Position -1), 75.05 A (Position -2) - Low Voltage: 1375 A Frequency: 50 Hz Cooling: ONAN Year of Manufacture: 1993 Status: In operation until 2025 Notable Condition: High CO levels, insufficient oil inhibitor content. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale - Manufacturer: ELIN - Model: JDR 8000/110 - Power Rating: 8 MVA - High Voltage: - 124.85 kV (Position 9) - 110 kV (Position 0) - 95.15 kV (Position -9) - Low Voltage: 25 kV - Current Rating: - High Voltage: 37.5 A (Position 9), 42.0 A (Position 0), 47.7 A (Position -9) - Low Voltage: 185 A - Frequency: 50 Hz - Cooling: ONAN - Year of Manufacture: 1960 - Status: Out of service since early 2024 - Notable Condition: Low oil inhibitor content and specific resistance; otherwise, oil is in good condition. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale Manufacturer: Brown Boveri Model: TRFKa 1350/30 Power Rating: 1350 kVA High Voltage: - 26.25 kV (Middle position) - 27.56 kV (Position 1) - 24.93 kV (Position 5) Low Voltage: 6.3 kV Current Rating: - High Voltage: 29.7 A (Middle position) - Low Voltage: 124 A Frequency: 50 Hz Cooling: ONAN Year of Manufacture: 1972 Status: In operation until March 2025 Notable Condition: High CO levels and water content; oil drying and treatment recommended. Find more here - / Contact us at -
used
Manufacturer: COMUNA-Metall Year of Manufacture: 2008 Gas type: Category 12HL Connection pressure: 20-50 mbar Nominal power range: 150/195 kW Voltage: 230/400V, 3-phase, 50Hz Fuse: NH 00, 100A Permissible operating pressure: 6 bar Thermal power: 100 kW Electrical power: 50 kW Protection class: IP 54 Permissible operating temperature: 90/70°C Find more here - / Contact us at -
used
2. Other and Auxiliary Systems SNA-17. Transformer Systems, Room K 14, Transformer 2 units Cast Resin Dry-Type Transformer Type GEAFOL TG 4951H, Built: 1990 Manufacturer: AEG Trafo Union Technical Data: - 800 kVA - Voltage level 10 kV / 0.4 kV - Dyn 5 Find more here - / Contact us at -
used
2. Other and Auxiliary Systems SNA-19. Water Recooling System - Room E 06, Water Recooler 2 units Cooling Compressor Systems BOGE C7 (Screw Compressor), functional, Built: 2015 Manufacturer: BOGE GmbH Technical Data: - 5.5 kW; 380V - 8/13 bar - 0.9 m³/h - Intake capacity: 5-50 Mm³/h - Mass: 0.21 t Find more here - / Contact us at -
used
SNA-21. 10 kV Switchgear 10 kV System 10 kV HS switchgear from Siemens Type 88J20, Built: 1993, system-specific Manufacturer: Siemens Technical Data: - 9 HS fields, metal-encapsulated - 2 input fields / 2 circuit breaker outlets - Coupling, measurement, etc. Find more here - / Contact us at -
used
Key Details: • Turbine: Solar Centaur 40 (Dual Fuel: Natural Gas & Diesel) • Power Rating: 3.5 MW • Total Running Hours: 40,000 since the last overhaul • Alternator: Hyundai, Air-Cooled, 3,500 kW, 50 Hz, 3,300V • Heat Recovery Boiler: Nebraska, 22-ton capacity • Gas Compressor & Control Panel included Spare parts available. Find more here - / Contact us at -
used
Manufacturer: Bell Maschinenfabrik Year of Manufacture: 1988/1989 Design: Horizontal Nozzles: 2 Flow Rate (Q): 2.1 m³/s Net Head (H Net): 209.5 m Power Output (P): 3750 kW Speed: 429 min⁻¹ Operating Hours: 285,000 by end of November 2024 Pelton Wheel: PN25 DN 700 The turbine is sold completely with bearing and control hydraulics, as well as turbine governor, controller, Pelton wheel, and housings, along with supply pipes. Spare runner (11,000 operating hours) is available. Optionally, the generator, including the turbine bearings from AvK, can also be taken over: 10.2 kV, air-cooled. Find more here - / Contact us at -
used
Manufacturer: KW Energie Model: Smartblock Year of Manufacture: 2014 Type of Machine: CHP Plant Operating Hours: 17,000 Fuel Type: Natural Gas Engine: Kubota Electrical Output: 22 kW Thermal Output: 50 kW (with condensing boiler use) Fuel Input: 68.4 kW Condition: Fully functional Motor Data - Model: Kubota R24 - Type: Four-Stroke Otto Engine - Cylinder Count: 4 - Displacement: 2.4 Liters - Nominal Speed: 1500 rpm Efficiency Data - Total Efficiency: 105.3% - Electrical Efficiency: 32.2% - Thermal Efficiency: 73.1% - Primary Energy Savings: 34.1% - Primary Energy Factor: 0.36 - Overall Annual Utilization Rate: 105.3% Gas Connection Data - Gas Supply Pressure: 20-50 mbar - Gas Flow Pressure: 16 mbar - Volume Flow (at 0°C, 1013 mbar): 6.8 Nm³/h Temperature Data - Flow Temperature: Max. 85°C - Return Temperature: Max. 65°C - Combustion Air Demand: Min. 75 m³/h - Room ...
used
Manufacturer: TEDOM Model: FLEXI 250 Year of Manufacture: 2022 Type of Machine: Combined heat and power plant (CHP) Primary Circuit - Nominal Heat Output: 369 kW - Max. Permissible Pressure: 3.5 bar - Max. Permissible Temperature: 95°C - Category: II - Nominal Size: 100 - Fluid: Water-Ethylene Glycol - Volume: 350 L Secondary Circuit - Nominal Heat Output: 369 kW - Max. Permissible Pressure: 10 bar - Max. Permissible Temperature: 90°C - Category: Article 4, Section 3 - Nominal Size: 80 - Fluid: Water-Propylene Glycol - Volume: 56 L Reversible heat pump Manufacturer: Mitsubishi Model: NX2-N-G06 /A /0606 Type: Reversible, air-cooled heat pump Function: Heating and cooling Power Supply: 400V / 3-phase / 50Hz Find more here - / Contact us at -
used
Manufacturer: Ansaldo Year of Manufacture: 1999 Technical Data Listing Generator - Type: Three-phase synchronous generator GSCR 800Y4 - Power: 7,250 KVA - Voltage: 10,500V - Frequency: 50 Hz - Phase Number: 3 - Number of Poles: 4 - Rated Current: 398.8A - Power Factor: 0.80 - Rated Speed: 1,500 rpm - Spin Speed: 1,800 rpm - Insulation Heat Resistance Class: F - Ambient Temperature: 40°C - Moment of Inertia of the Rotor: 118.75 kgm² - Winding Connection: Star - Excitation Voltage Rating: 41.2/158.3V - Rated Excitation Current: 54.2/152.3A - Operation Mode: Continuous - Protection Class: IP 4 - Cooling Water Quantity: 660 l/min - Cooling Water Inlet Temperature: 40°C - Cooling Water Inlet Pressure: 4 bar - Air Inlet Temperature: 45°C - Bearing Type: Rolling bearing - Bearing A-side: EMZLB18-200 - Bearing B-side: EMZLQ18-200 - Min. Clearance Shaft/Bearing: 0.267mm - Max. Clearance S ...
We are currently offering for sale an almost new 50 kW CHP plant from Tuxhorn. Specifications: - Model: E50SW (Natural Gas Version) - Year of Manufacture : 2022 - Commissioning Date: February 2023 - Operating Hours (BH): 45 - Number of Starts: 59 Special Features: - Equipped with a second exhaust gas SD, reducing exhaust noise to as low as 35 dB(A) for quieter operation. Condition: - Excellent: The unit is in like-new condition with minimal usage. Applications: - Ideal for industrial or commercial operations requiring reliable and efficient combined heat and power. Find more here - / Contact us at -
used
Thermostat, Cooling Water Temperature Controller, Thermostatic MERTIK542.83Switching Temperature: 80° CMain Connections: Ø 50 mmSecondary Connection: Ø 32 mmMaterial: BrassNew !Dimensions: 180 x 160 x 100 mm
used
Frequency converter, frequency converterLOHERFUV 160L2/160L1/6Input: 380 V 28 AOutput: 265 V 48 A 200 HzPower: 22 KVAused, tested ! Image similar !Dimensions: 1030 x 540 x 340 mm
used
GeneratorAEMWH 400 L 4690 V910 kW60 Hz1815 rpmshaft diameter: Ø 110 mmDimensions: 2200 x 1400 x 1100 mmWeight approx. 3..8 TonNew !
used
DC Generator for DDR Crane MotorsVEMGGB 180.1K ( GGB180.1K )TGL 20675 ( TGL20675 )6.2 kW230 V DCmotor: 7.5 kW1435 rpm380 Vused, tested ! Dimensions: 1090 x 360 x 540 mm
used
GeneratorEMEDRS 200/10-8year: 2005115 V52,2 A107 HzShaft diameter: Ø 40 / 45 mmNew !' Dimensions: 730 x 460 x 470 mm
used
2007 Mercedes Combined heat and power plant (CHP) The CHP plant was originally intended for an oil platform. Therefore, it is protected against salt water and can also be operated in island mode. Technical data (See pictures) CHP plant with Mercedes engine, which is designed for multi-quality fuel (diesel, heating oil, pyrolysis oil or vegetable oil). Thus preheating unit and corresponding exhaust gas purification. BJ. 2007. Operating hours: 0 (test run only); The unit was never connected to the network. If palm or vegetable oil is used, preheating” is required to get above the pour point. All pumps were completely overhauled by the manufacturer when we purchased them (see Rg with maintenance report). If you want to drive in island mode, this must be changed on the control + the controller on the generator must be replaced. In addition to electricity, the unit can also recover ...
used
Engine: Jenbacher Works 4T6S Generator: 725kW Diesel powered We installed the unit in a 20-foot container a few years ago. It is fully functional and working. Find more here - / Contact us at -
used
Backup power generator LIKE NEW! The current number of operating hours is 21 hours . Manufacturer Zeppelin CAT Model PPO2000-C32 Year of manufacture 2007 Weight 26t Dimensions (L/W/H) 11,0m / 3,0m / 3,2m Condition Very good (used) Remarks/ Info: Engine overhauled in 2014 400 Volt 50 Hz 1200 KW 2000 kVA 1500 rpm According to this, the CAT engines have been completely reconditioned (according to Zeppelin, the engine is better in the repair ,as a new engine) . The current number of operating hours is 21 hours . The machine has been standing since 2014 . We were to a performance test last month at Cat Zeppelin ,there the machine has full power without complaint passed the test . The number of operating hours refers to both engines and the generator. Find more here - /
used
2x Tapping back-pressure turbine with spur gearbox and generator Nr1: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 3800 kW Speed: l0000 rpm Steam inlet pressure max. : 37 Steam inlet temperature max. 44 degrees Tapping pressure max. : 24 Tapping temperature : 390 degrees Evaporation pressure : 2 Normal absorption capacity : 27 t/h Maximum absorption capacity : 32 t/h Gearbox Make Voith, St.Pölten Type D 64 Rated power: 5,700 HP Speed 10 OOO/1 5oo rpm Backpressure steam turbine + gearbox + synchronous generator incl. auxiliaries Nr2: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 43oo kW Speed: 9900 rpm Steam inlet pressure max. 24 atü Steam inlet temperature max. 42o 00 Exhaust steam pressure 2 ata Normal absorption capacity 35 t/h Maximum absorption capacity 35.7 t/h Gearbox Make BHS ...
used
Power plant (Lambion-Howden-Scheuch-Hamworthy) History - Commissioning: 2009 - Power plant built for the heat supply Manufacturer: Lambion Siemens (turbine, measurement and control technology) Imtech (electrics and performance data: 950 kW rated electrical power 2.00 MW rated thermal output HT(128 128°C) 1.50 MW thermal output NT (85 85°C) 6.74 MW thermal firing capacity Steam output: 7.5 t/h approx. 11,000 tonnes of fuel required per year LPM and WHS Boiler Manufacturer Lambion Year of construction 2008 Maximum steam production [t/h] 7.5 Max. permissible pressure [bar] 32 Max. permissible vapour temperature [ [°C] 440 Turbine / Generator manufacturer Howden Machine TWIN CA 34 Year of construction: 2008 Generator manufacturer: AvK Generator Generator type: DSG 74 M2 System data: Flue gas cleaning Manufacturer Scheuch Condenser / recooling manufa ...
used
used very little (max 4000 hours) and are in excellent condition. ORC turbine of 160 kW electrical and about 700 kW thermal, Since 2001, Triogen has been developing and manufacturing systems for conversion Organic Rankine Cycle (ORC) energy conversion systems. The generator TRIOGEN ORC, which has been used in various application areas since since 2005, is similar to a steam cycle, but uses a fluid organic instead of water. Compared with steam, it allows to achieve better performance and efficiencies by exploiting sources of low-temperature heat. The Triogen ORC generator is suitable for the conversion of heat from: + Natural gas engines + Biogas engines + Landfill gas engines + Biomass + Biodiesel engines + Diesel engines + Gas from flares + Gas turbines + Process heat + Furnace heat + Any heat source >350 °C 165 kWe DI ELECTRICITY WITHOUT FUEL AND EMISSION-FREE ...
used
3X Identical Steam Turbine sets Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required. The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz. Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine. The unused steam turbine sets are pa ...
used
Model: DOTR 63000/123 Rated Power: 50 / 63 MVA High Voltage (HV): 115 kV High Voltage Tapping Range: +9 / -9 x 1.778% (adjustable under load) Insulation Level HV: 123/550/230 kV Low Voltage (LV): 31.5 kV Insulation Level LV: 36/170/70 kV Tertiary Voltage: 6 kV Insulation Level TW: 12/75/28 kV Frequency: 50 Hz Vector Group: Yynyn0(d) Cooling Method: ONAN / ONAF Maximum Oil Temperature Rise: 60 K Maximum Winding Temperature Rise: 65 K Ambient Temperature Range: -25°C to 40°C Impedance: - At 50 MVA: 15.8% (± IEC-Tolerance) - At 63 MVA: 21% (±7.5%) No-Load Losses: 12.5 kW (+IEC-Tolerance) Load Losses at 50 MVA: 154 kW (+IEC-Tolerance) Noise Power Level at ONAF (No Load): 80 dB(A) Weight Details: - Shipping Weight: Approx. 87,500 kg - Weight of Oil: Approx. 15,300 kg - Active Part: Approx. 58,500 kg - Total Weight: Approx. 89,800 kg Dimensions: - Shipping Dimensions ...
used
Steam Turbine 1 and major components Plant part Manufacturer Year of construction techn. data turbine VEB EKM 1970 generator VEB EKM; VEB Bergmann Borsig 1970 31250 kVA x 6,3 kV condenser VEB EKM 1970 "Bearing oil plant, pumps, "VEB Apparatebau Leisnig-Tragnitz; Filter Cooler" VEM, Siemens, VEB EKM and KSB" 1969 Steam jet cleaner Wilhelm Wigand ca. 1970 Condensate pumps VEB EKM ca. 1970 Find more here - / Contact us at -