We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Manufacturer:
(Category: 1101)
used
Backup power generator LIKE NEW! The current number of operating hours is 21 hours . Manufacturer Zeppelin CAT Model PPO2000-C32 Year of manufacture 2007 Weight 26t Dimensions (L/W/H) 11,0m / 3,0m / 3,2m Condition Very good (used) Remarks/ Info: Engine overhauled in 2014 400 Volt 50 Hz 1200 KW 2000 kVA 1500 rpm According to this, the CAT engines have been completely reconditioned (according to Zeppelin, the engine is better in the repair ,as a new engine) . The current number of operating hours is 21 hours . The machine has been standing since 2014 . We were to a performance test last month at Cat Zeppelin ,there the machine has full power without complaint passed the test . The number of operating hours refers to both engines and the generator. Find more here - /
used
2x Tapping back-pressure turbine with spur gearbox and generator Nr1: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 3800 kW Speed: l0000 rpm Steam inlet pressure max. : 37 Steam inlet temperature max. 44 degrees Tapping pressure max. : 24 Tapping temperature : 390 degrees Evaporation pressure : 2 Normal absorption capacity : 27 t/h Maximum absorption capacity : 32 t/h Gearbox Make Voith, St.Pölten Type D 64 Rated power: 5,700 HP Speed 10 OOO/1 5oo rpm Backpressure steam turbine + gearbox + synchronous generator incl. auxiliaries Nr2: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 43oo kW Speed: 9900 rpm Steam inlet pressure max. 24 atü Steam inlet temperature max. 42o 00 Exhaust steam pressure 2 ata Normal absorption capacity 35 t/h Maximum absorption capacity 35.7 t/h Gearbox Make BHS ...
used
Power plant (Lambion-Howden-Scheuch-Hamworthy) History - Commissioning: 2009 - Power plant built for the heat supply Manufacturer: Lambion Siemens (turbine, measurement and control technology) Imtech (electrics and performance data: 950 kW rated electrical power 2.00 MW rated thermal output HT(128 128°C) 1.50 MW thermal output NT (85 85°C) 6.74 MW thermal firing capacity Steam output: 7.5 t/h approx. 11,000 tonnes of fuel required per year LPM and WHS Boiler Manufacturer Lambion Year of construction 2008 Maximum steam production [t/h] 7.5 Max. permissible pressure [bar] 32 Max. permissible vapour temperature [ [°C] 440 Turbine / Generator manufacturer Howden Machine TWIN CA 34 Year of construction: 2008 Generator manufacturer: AvK Generator Generator type: DSG 74 M2 System data: Flue gas cleaning Manufacturer Scheuch Condenser / recooling manufa ...
used
used very little (max 4000 hours) and are in excellent condition. ORC turbine of 160 kW electrical and about 700 kW thermal, Since 2001, Triogen has been developing and manufacturing systems for conversion Organic Rankine Cycle (ORC) energy conversion systems. The generator TRIOGEN ORC, which has been used in various application areas since since 2005, is similar to a steam cycle, but uses a fluid organic instead of water. Compared with steam, it allows to achieve better performance and efficiencies by exploiting sources of low-temperature heat. The Triogen ORC generator is suitable for the conversion of heat from: + Natural gas engines + Biogas engines + Landfill gas engines + Biomass + Biodiesel engines + Diesel engines + Gas from flares + Gas turbines + Process heat + Furnace heat + Any heat source >350 °C 165 kWe DI ELECTRICITY WITHOUT FUEL AND EMISSION-FREE ...
used
3X Identical Steam Turbine sets Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required. The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz. Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine. The unused steam turbine sets are pa ...
used
Model: DOTR 63000/123 Rated Power: 50 / 63 MVA High Voltage (HV): 115 kV High Voltage Tapping Range: +9 / -9 x 1.778% (adjustable under load) Insulation Level HV: 123/550/230 kV Low Voltage (LV): 31.5 kV Insulation Level LV: 36/170/70 kV Tertiary Voltage: 6 kV Insulation Level TW: 12/75/28 kV Frequency: 50 Hz Vector Group: Yynyn0(d) Cooling Method: ONAN / ONAF Maximum Oil Temperature Rise: 60 K Maximum Winding Temperature Rise: 65 K Ambient Temperature Range: -25°C to 40°C Impedance: - At 50 MVA: 15.8% (± IEC-Tolerance) - At 63 MVA: 21% (±7.5%) No-Load Losses: 12.5 kW (+IEC-Tolerance) Load Losses at 50 MVA: 154 kW (+IEC-Tolerance) Noise Power Level at ONAF (No Load): 80 dB(A) Weight Details: - Shipping Weight: Approx. 87,500 kg - Weight of Oil: Approx. 15,300 kg - Active Part: Approx. 58,500 kg - Total Weight: Approx. 89,800 kg Dimensions: - Shipping Dimensions ...
used
Steam Turbine 1 and major components Plant part Manufacturer Year of construction techn. data turbine VEB EKM 1970 generator VEB EKM; VEB Bergmann Borsig 1970 31250 kVA x 6,3 kV condenser VEB EKM 1970 "Bearing oil plant, pumps, "VEB Apparatebau Leisnig-Tragnitz; Filter Cooler" VEM, Siemens, VEB EKM and KSB" 1969 Steam jet cleaner Wilhelm Wigand ca. 1970 Condensate pumps VEB EKM ca. 1970 Find more here - / Contact us at -
used
a) 3-phase dry-type transformer for indoor use, manufacturer: Siemens AG (Trafo-Union) 3) Electrical power: 1,250 kVA Brief description In-plant location Year of construction Three-phase three-phase transformer, three separate windings, electrical output: 1,250 kVA Manufacturer type: 4GD6164-3ZY Dimensions: 3.5m x 2.40 x 3m Weight: approx. 3 tonnes Accessories: - Reactive current control Dimensions: approx. 1m x 1m x 3m - Low-voltage main distribution board (NSHV 1) Dimensions length approx. 3.6m x width 1m x height 3m, Find more here - / Contact us at -
used
3-phase dry-type transformer for indoor use, manufacturer: Siemens AG (Trafo- Union) electrical power: 1,250 kVA Year of construction: 2013 Three-phase three-phase transformer, three separate windings windings, electrical power: 1,250 kVA Manufacturer type: 4GD6164-3ZY Dimensions: 3.5m x 2.40 x 3m Weight: approx. 3 tons Accessories: - Reactive current control Dimensions: approx. 1m x 1m x 3m - Low-voltage main distribution board (NSHV 1) Dimensions Length approx. 3.6m x width 1m x height 3m, 4 doors 3-phase dry transformer for interior, manufacturer: Siemens AG (Trafo- Union) Year of construction 2015 Three-phase three-phase transformer, three separate windings windings, electrical power: 1,000 kVA Manufacturer type: 4GD6164-3ZY Dimensions: 3.5m x 2.40 x 3m Weight: approx. 3 tons Accessories: - Reactive current control Dimensions: approx. 1m x 1m x 3m - Low-voltage ...
used
Heat and Power Plant with an Absorption Chiller An 850 kW combined heat and power plant with an absorption chiller. The systems ran perfectly until the end and all maintenance was carried out. No damage is known. The CHP ran for 51,429 hours of operation. The absorption chiller has run for 42,350 hours. The following components use an overhauled long block or completely overhauled. The components relevant to assemblies for "modernization" were marked: - complete panelling - Interfaceschronk - Oil relubrication pump Mechanically overhauled and electrically tested - Oil level monitoring - Plotter heat exchanger" - Pressure expansion foll3 (if present) - Pressure transducer and temperature sensors - Rubber rails for motor and generator - Clutch element - Air filter inserts - Safety valves and arnot inserts - Sylomer strips - Hot water preheating pump and heating el ...
used
BHKW engine type HCI534E2 for sale Combustion engine TEDOM type DC16 1-013-826. The motor block was only completely replaced in May 23 It is still entitled to EEG compensation until 2031. Find more here - / Contact us at -
used
Steam turbine for sale. The turbine was built in 2012, is in good condition and is no longer in operation. Model SST-060 Turbine with impeller in so-called constant-pressure design ("action wheel"). The turbine rotor is mounted on two bearings and consists of the above-mentioned impeller and a shaft, which are connected to each other by means of Hirth gearing. The impeller is located outside the bearing and consists of one piece. The blades are milled out of the solid disc. Live steam pressure: 13.0 ´bara at turbine flange Live steam temperature: 191.6 ´C at turbine flange Live steam flow max: 10,000 kg/h Exhaust steam pressure: 5.2 bara at turbine exhaust flange Turbo generator sound pressure level: 92 dB(A) z 3 dB(A) measured at a distance of 1 m Coupling power: 275kW Total terminal power: The tolerance is 1.0%. 265kWe The pressure drop for the cyclone to be provided sh ...
used
2x GE Frame 6B gas turbines # Technical Summary Equipment Details - Gas Turbines: Two GE MS 6001 B gas turbines paired with AEG generators (Type S7102/2). - Operation History: - Commissioning: 1981 - Gas-fired Operation: Until 2005, primarily for base load (~7000 hours/year). - Operational Hours in Combined Cycle: - GT21: ~167,000 hours, ~1130 starts - GT22: ~159,000 hours, ~1180 starts - Retrofitted: In 1996 with water injection for NOx reduction. - Conversion: In 2007 to peak load operation using heating oil (HEL) with new steel chimneys and upgraded control systems to ABB Procontrol 14. - Operational Hours in Peak Load: - GT21: ~130 hours, ~177 starts - GT22: ~150 hours, ~180 starts - Last Network Operation: 2015 - Last Oil Service: - GT21: October 2015 - GT22: September 2016 - Last Borescope Inspection: December 2016 - Defect: Heating oil transfer line issue in 2 ...
new
Key data: 648 KW, 810 kVA
Caterpillar 3412C Generator Sets – 2014, Unused • Quantity: 9 units • Prime Power: 810 kVA / 648 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3412C diesel • Condition: Unused, factory new Key Features: IP22 protection, H insulation, standard CAT excitation, suitable for industrial continuous-duty applications in 50 Hz markets. Caterpillar 3406C Generator Sets – 2014, Unused • Quantity: 5 units • Prime Power: 275 kVA / 220 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3406C diesel • Condition: Unused, factory new Key Features: IP23 enclosure, H insulation, star-connected generator, ambient rating up to 50°C.
new
Key data: 648 KW, 810 kVA
Caterpillar 3412C Generator Sets – 2014, Unused • Quantity: 9 units • Prime Power: 810 kVA / 648 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3412C diesel • Condition: Unused, factory new Key Features: IP22 protection, H insulation, standard CAT excitation, suitable for industrial continuous-duty applications in 50 Hz markets. Caterpillar 3406C Generator Sets – 2014, Unused • Quantity: 5 units • Prime Power: 275 kVA / 220 kW • Voltage / Phase: 400/230 V, 3‑phase • Frequency / Speed: 50 Hz, 1500 RPM • Power Factor: 0.8 • Engine: CAT 3406C diesel • Condition: Unused, factory new Key Features: IP23 enclosure, H insulation, star-connected generator, ambient rating up to 50°C.
used
Key data: 19305 KW, 24132 kVA, 11000 V
We are pleased to present the data and technical information for a MAN-based power plant with total capacity of 58 MW, including full operational history. Below is our sale proposal for three (3) MAN 18V48/60 TS diesel generator sets, offered together with Balance of Plant (BOP). 1. Engine Details Manufacturer: MAN Turbo & Diesel Model: 18V48/60 TS Rated Output: 19,305 kW (continuous) per unit Fuel: HSD (diesel); can be converted to HFO with fuel heating system modification Speed: 500 RPM Serial Numbers: 1135657, 1135658, 1135659 2. Alternator Details Manufacturer: ABB Rating: 24,132 kVA Voltage: 11,000 V Frequency: 50 Hz Power Factor: 0.8 3. General Information Quantity: 3 generator sets Manufacturing Year: 2014 First Operation: January 2016 Average Running Hours: approx. 5,000–6,000 hours Status: Very good condition, fully operational Application: B ...
used
used
used
used
used
used
used
used
used
used
used
used
used