We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
134,391 used machines on RESALE, but how to find them? Machine Search
used
Seller: EURO MARINE SERVICES
HYDRAULIC PUMPS - 3Nos MAKE: KAWASAKI HEAVY Ind. JAPAN TYPE: BZ732S215LH REGISTERED TYPE: R3041L-2SOL
used
Engine Brand: KAWASAKI, Conditie: USED, Engine Cooling Type: Oil Cooled , Engine Color: Grey , Working Hours: 1232 Hour(s), Engine Condition: Used , Turbo Type: None Mounted , Exhaust System: Dry , ECU Present?: no , Starter Voltage: 24 Volt , Rated Power: 1180 Kw, Rated Speed: 1500 Rpm, Injection Type: Mechanical Fuelpump , Generator KVA: 1250 , Generator Hz: 50 , Generator Volts: 400 , Generator Amps: 1804 , Generator Fases: 3 Fases , , https://www.hamofa.com/catalog/product/view/id/203827, , = More information =, , Empty weight: 12.000 kg, Type number: Kawasaki M1A-01 GENERATOR 1250 K
used
Seller: Gas Engine Exchange Ltd
Kawasaki M7A-03D 7.2MW Natural Gas Turbine Complete CHP Generating Set Completely self-contained Kawasaki M7A-03D 7.2MW Gas Turbine and Generator package with Heat Recovery (Thermic Fluid Heater and HRSG Hot Water Generator) in acoustic enclosure. Runs parallel with grid. Island operation mode. Make and Model: Kawasaki TD80A Capacity: 7200kW Hrs: 10,000 V: 11,000 HZ: 50 Year: 2010 Fuel: Natural Gas Scope of supply: Gas Turbine GPB 80, M7A-03 DLE Single Gas Fuel, single shaft with DLE Combustor, reduction gear box, coupling with guard, Diaphragm Type, Generator (TD80A, 2011) Heat Recovery System - Thermic Fluid Heater, HRSG Hot Water Generator Acoustic Canopy with Lighting Control and Instrumentation Exhaust collector and/or diffuser, Gas Fuel system, Lube oil system, Inlet ducting, Inlet filtration system, Inlet silencer, Combustion system, Protection system ...
used
Seller: Kandlin Stromerzeuger-Ankauf GmbH
Key data: 1425 KW, 1600 kVA, 6300 V
Kawasaki Gas Turbine GPB 15D Gas turbine from 2006 with 32,000 operating hours, 1 available 1,280 KWel x 1,500 rpm, 6,300 V/50 Hz. AC Generator: AEM SEH 500 L4, 1,600 KVA Manufacturer: Kawasaki Model No.: M1A-13D Type: Gas Turbine Serial Number: KHI-1012 Power [KW]: 1,425 Year of Make: 2006 Operating hours: approx. 32,000 Weight unit [kg]: 12,000 Dimensions unit LxWxH [cm]: 870 x 290 x 310 AC Generator Manufacturer: AEM Model: SEH 500 L4 Type: AC Synchronous Generator Serial number: 3085 00218 Power [KVA]: 1,600 Voltage [V]: 6,300 Frequency [Hz]: 50 Current [A]: 175 Speed [1/min]: 1,500 Year of Make: 2006 Weight [kg]: 6.460
used
34 MW Kawasaki Gas Turbine Overview A well-maintained, low-hour 34 MW gas turbine cogeneration power plant is available for acquisition. The facility commenced commercial operation in August 2021 and has accumulated approximately 13,298 operating hours as of May 25, 2023, with projected total operating hours of approximately 20,000 hours by March 2024. The plant will be available for delivery beginning July 2026. Designed for high-efficiency combined heat and power (CHP) applications, the facility incorporates a Kawasaki L30A gas turbine, heat recovery steam generation system, and steam absorption chiller, delivering excellent overall thermal efficiency while maintaining low emissions through Dry Low Emission (DLE) combustion technology. Plant Highlights Commercial operation date: August 2021 Manufacturer: Kawasaki Heavy Industries, Japan Manufacturing year: August 2020 ...
used
Kawasaki Gas Turbine Cogeneration Power Plant 34 MW / 60 Hz This modern 34 MW Kawasaki L30A Gas Turbine Power Plant is a highly efficient and environmentally friendly cogeneration facility designed for industrial and utility-scale power generation. Manufactured in 2020 and maintained in excellent condition, the plant combines reliable electrical generation with heat recovery, achieving total fuel utilization efficiency of up to 85.5%. Operation was stopped on Stopped in March 2024 in good condition and the plant was preserved with KHI’s maintenance instructions. The plant is powered by a Kawasaki L30A two-shaft industrial gas turbine featuring a 14-stage axial-flow compressor, advanced Dry Low Emission (DLE) combustion system and high-efficiency turbine technology. The unit delivers approximately 34 MW electrical output with thermal efficiency exceeding 41%, while maintaining exce ...
used
Seller: M&S EXPORT Lippstadt
Dear Ladies and Gentlemen, We constantly have transformer stations for wind turbines in every power and voltage.
used
Manufacturer: Bell Maschinenfabrik Year of Manufacture: 1988/1989 Design: Horizontal Nozzles: 2 Flow Rate (Q): 2.1 m³/s Net Head (H Net): 209.5 m Power Output (P): 3750 kW Speed: 429 min⁻¹ Operating Hours: 285,000 by end of November 2024 Pelton Wheel: PN25 DN 700 The turbine is sold completely with bearing and control hydraulics, as well as turbine governor, controller, Pelton wheel, and housings, along with supply pipes. Spare runner (11,000 operating hours) is available. Optionally, the generator, including the turbine bearings from AvK, can also be taken over: 10.2 kV, air-cooled. Find more here - / Contact us at -
used
2x Tapping back-pressure turbine with spur gearbox and generator Nr1: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 3800 kW Speed: l0000 rpm Steam inlet pressure max. : 37 Steam inlet temperature max. 44 degrees Tapping pressure max. : 24 Tapping temperature : 390 degrees Evaporation pressure : 2 Normal absorption capacity : 27 t/h Maximum absorption capacity : 32 t/h Gearbox Make Voith, St.Pölten Type D 64 Rated power: 5,700 HP Speed 10 OOO/1 5oo rpm Backpressure steam turbine + gearbox + synchronous generator incl. auxiliaries Nr2: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 43oo kW Speed: 9900 rpm Steam inlet pressure max. 24 atü Steam inlet temperature max. 42o 00 Exhaust steam pressure 2 ata Normal absorption capacity 35 t/h Maximum absorption capacity 35.7 t/h Gearbox Make BHS ...
used
2x GE Frame 6B gas turbines # Technical Summary Equipment Details - Gas Turbines: Two GE MS 6001 B gas turbines paired with AEG generators (Type S7102/2). - Operation History: - Commissioning: 1981 - Gas-fired Operation: Until 2005, primarily for base load (~7000 hours/year). - Operational Hours in Combined Cycle: - GT21: ~167,000 hours, ~1130 starts - GT22: ~159,000 hours, ~1180 starts - Retrofitted: In 1996 with water injection for NOx reduction. - Conversion: In 2007 to peak load operation using heating oil (HEL) with new steel chimneys and upgraded control systems to ABB Procontrol 14. - Operational Hours in Peak Load: - GT21: ~130 hours, ~177 starts - GT22: ~150 hours, ~180 starts - Last Network Operation: 2015 - Last Oil Service: - GT21: October 2015 - GT22: September 2016 - Last Borescope Inspection: December 2016 - Defect: Heating oil transfer line issue in 2 ...
used
6.6 MW MAN THYSSEN Extraction Condensing Steam Turbine Manufacturer: MAN THYSSEN Year of Construction: 1999 Condition: Used – In Good Running Condition Availability: In Stock Technical Data: Rated Power Output: 6.6 MW Voltage: 11 kV Frequency: 50 Hz Steam Inlet Conditions: Pressure: 40 bar Temperature: 440 °C Extraction Performance: 6 MW with 50 t extraction – 65 t/h 6 MW with 16 t extraction – 45 t/h 5 MW with 0 t extraction – 28 t/h Extraction Steam: Pressure: 12 bar Temperature: 294 °C Exhaust Steam: Pressure: 0.25 bar Temperature: 65 °C Description: Well-maintained German manufactured extraction condensing steam turbine suitable for industrial power generation and combined heat and power applications. The unit is designed for continuous operation and is ideal for sugar mills, textile plants, paper mills, chemic ...
used
Manufacturer: Siemens Model: SST-060 Year of Manufacture: 2016 Output Power: 1006 kW (nominal) Speed: 1500 rpm (nominal) Trip Speed: 1605 rpm Live Steam (Inlet Pressure): - Min: 20.6 bar - Nominal: 23.0 bar - Max: 25.4 bar Live Steam (Inlet Temperature): - Min: 300 °C - Nominal: 350 °C - Max: 378 °C Exhaust Steam (Outlet Pressure): - Min: 2.10 bar - Nominal: 3.10 bar - Max: 4.10 bar Exhaust Steam (Outlet Temperature): - Max: 331 °C Find more here - / Contact us at -
used
10 MW W H-ALLEN Bedford England Back Pressure Steam Turbine Manufacturer: W H-ALLEN, Bedford, England Type: Back Pressure Steam Turbine Condition: Used – In Good Industrial Condition Availability: In Stock Technical Specifications: Rated Power Output: 10 MW Rated Speed: 7,750 RPM Voltage: 11 kV Frequency: 50 Hz Steam Conditions: Inlet Steam Pressure: 44.8 bar g Inlet Steam Temperature: 400 °C Exhaust Steam Pressure: 1 to 5.2 bar g Heavy-duty British-manufactured back pressure steam turbine designed for continuous industrial power generation and process steam applications. This unit is suitable for combined heat and power systems in sugar mills, textile plants, paper mills, chemical industries, and other steam-based manufacturing facilities. The turbine operates at high efficiency with stable back pressure performance, making it ideal for facili ...
used
Manufacturer: KKK Model: CF 5 G Year of Manufacture: 1986 Output Power: 412 kW Inlet Steam Pressure: 19 bar (Normal) Outlet Steam Pressure: 3 bar (Normal) Inlet Steam Temperature: 300°C (Normal) Alternator Features: Brand: AVK Alternator Type: DKBN80/500-4TS Power: 482 KVA (400 V, 696 A, 50 Hz) Year of Manufacture: 1986
used
20 MW STAL-LAVAL Industrial Steam Turbine Generator Set Manufacturer: STAL-LAVAL (Sweden) Type: Industrial Multi-Stage Steam Turbine Configuration: Condensing / Extraction-Condensing Manufacturing Era: Circa 1963–1964 Condition: Industrial Condition – Available for Inspection Availability: In Stock Power & Electrical Data: Rated Output: Approx. 20 MW Frequency: 50 Hz Rated Speed: 3000 RPM Generator: STAL-LAVAL GTP Series Generator Poles: 2-Pole Turbo Alternator Cooling System: Radial-flow air ventilation with filtration Coupling: Direct-coupled turbine-generator set Steam Design Parameters: Steam Pressure Class: Approx. 65 bar Steam Temperature (Design): Approx. 480–520 °C Operating Mode: Condensing turbine with surface condenser (extraction capable) Exhaust System: Shell and tube surface condenser Technical Features: Curtis con ...
used
Manufacturer: AEG Germany Equipment Type: Back Pressure Steam Turbine Generator Power Output: 11,200 kVA (≈ 9 MW) Voltage: 6.5 kV Frequency: 50 Hz Speed: 3000 RPM Generator Type: S 688/4 Condition: Available As-Is, Where-Is Technical Specifications Electrical Output: 11,200 kVA (9 MW) Inlet Steam Pressure: 65 bar Inlet Steam Temperature: 440 °C Steam Consumption (Full Load): 60 tons/hour Exhaust Steam Pressure: 2.5 bar (Max) Exhaust Steam Temperature: 190 °C Voltage: 6.5 kV Frequency: 50 Hz Speed: 3000 RPM Generator Insulation Class: B Description High-capacity AEG Back Pressure Steam Turbine Generator designed for industrial power generation and energy recovery applications. This 9 MW steam turbine system is suitable for industries with continuous steam availability such as: Sugar mills Textile mills Chemical plants Paper mil ...
new
Titan T250 Specifications Condition New / Never Used Status Disconnected. Preservation inspection was done in the Fall of 2020 and another inspection in 2022. Manufactured Solar Turbines 2017 Driver Solar Turbines Titan 250 Natural Gas Turbine / Version 30002S CS/MD Max HP 30,000 HP Rated RPM 10,500 RPM Control Panel Solar Turbotronic CTLM02